HomeContact usConsignmentEquipmentProcess unitsEspañolEnglish



Ventech Engineers, Inc.

Ventech Engineers Int'l Corp.

Ventech Process Equipment, Inc.

Ventech Appraisal Services, Inc.

1149 Ellsworth
P.O. 4261
Pasadena, Texas 77502
Map
Directions
(713) 477-0201 phone
(713) 477-2420 fax
 

 

 


   Distillate Desulfurizer Unit (DDS)

The Distillate Desulfurizer Unit (DDS), Unit 17, was originally installed in the early 1960’s. This unit is a conventional Gulf Oil 750 psig design with a two drum reactor effluent separation system.  

Most of the equipment in this unit is from the 1960’s.  The low pressure separator drum which was replaced in 1978.  The unit was also revamped in 1995 with the addition of a third charge pump to its existing capacity of 6,800 KPSD.  A new reactor and hydrogen compressor were installed in 1998. 

The reactor vessel is 4.3’ diameter by 78’ high, rated at a design pressure of 883 psig, chrome-moly with 347 stainless lining metallurgy and has 3 catalyst beds.  The reactor is installed in a new bolted support structure.  Unit pressure is still constrained at approximately 750 psig  by the reactor products high-pressure separator design.  The fired heater 17H1 is a combined fresh feed and stripper reboiler heater rated at 10 MMBTU/hr and of twin cabin type construction.  The dry stripper is a 20-tray column with a bottoms recirculation reboiler. 

Click here for process description

Process Flow Diagram

Equipment List

 

 

 