Edmonton Refinery Units

  • Plant 1- Atmospheric Crude Fractionation Unit, 80,000 BPD

  • Plant 7 - Vacuum Distillation Unit, 29,000 BPD

  • Plant 13 - Delayed Coking Unit, 9,800 BPD

  • Plant 14 - Amine Treating Unit, 14.3 MMSCFD

  • Plant 15 - Sulphur Plant, 2200 MSCFD

  • Plant 53 - Steam-Methane Reforming Unit, 13.5 MMSCFD

  • Plant 55 - Pressure Swing Adsorption Unit, 31.4 MMSCFD

  • Plants 2, 4, 31, 34, 52 & 63

  • 1149 Ellsworth
    P.O. 4261
    Pasadena, Texas 77502
    Map
    Directions
    (713) 477-0201 phone
    (713) 477-2420 fax
     

     

     


      

    Edmonton Refinery - Plant 14

     

    Amine Treating Unit (fuel gas plant)

     

    The function of the amine treating unit is two-fold.  The first function is to process the H2S rich (sour) off gases produced by many plants throughout the refinery into a low H2S content gas of less than 50 wtppm suitable for use as fuel gas throughout the refinery.  The final refinery fuel gas is mixture of the treated off gases and natural gas make up.  A solution called lean amine is used to physically absorb the H2S from the offgases; the H2S bearing liquid is then called rich amine.

    The second function of the amine treating unit is to produce a gas stream containing mostly H2S from the rich amine stream created in the first process function and from other sources in the refinery.  The lean amine solution used in the refinery is a mixture of approximately 20% diethanolamine (DEA) and 80% water.

    The main sources of sour off gas in the refinery are the bulk desulphurization unit (Plant 2), the saturated gas plant (Plant 4), the unsaturated gas plant (Plant 9), the light cycle oil hydrotreater (Plant 10), and the hydrocracking unit and syncrude gas plant (Plant 52).  Each of these process units contains product streams which are a result of catalytic processes which convert organic sulphur containing hydrocarbons into H2S.

    The sources of rich amine stream are the bulk desulphurization unit (Plant 2)saturated gas plant (Plant 4), the unsaturated gas plant (Plant 9), the light cycle oil hydrotreater (Plant 10), the alkylation unit (Plant 12), and the syncrude gas plant (Plant 52).

    General Information:

    Refinery Area:

     

    Utilities area, Block F

    Process Name:

     

    Amine treating unit (fuel gas plant)

    Process Technology:

     

    not applicable

     

     

     

    Commissioned Date:

     

    1971

    Major Revamps:

     

    none

     

     

     

    Nameplate Capacity:

     

    14.3 MMSCFD

    Major Feedstock(s):

     

    sour gas streams from throughout the refinery, natural gas, and rich amine

    Major Product(s):

     

    hydrogen sulfide rich gas, lean amine, and refinery fuel gas

    Process Flow Diagram (PDF)

    Plot Plan (PDF)

    Equipment List


    [BACK TO OTHER UNITS]
     


     