Plant 7 EQUIPMENT - VACUUM DISTILLATION UNIT
| HEAT EXCHANGERS | ||||||||||||
| SHELL | TUBE | |||||||||||
| PICS | Item | Description | Area | Press. (PSIG) | Temp. (F) | Press. (PSIG) | Temp. (F) | Shell Material | Tube Material | TYPE | ||
| 7-E-1 | Vacuum Bottoms Cooler | 1,557 | 125 | 800 | 105 | 650 | SA-387-5 | SA-213-T5 | AFU | |||
| 7-E-2A/B | Steam Generator | |||||||||||
| 7-E-4 | Gas Oil Cooler | 3,780 | 207 | 650 | 108 | 650 | CS | CS | AES | |||
| COLUMNS | ||||||||||||
| Trays | ||||||||||||
| PICS | Item | Description | Diameter (Inches) | Height (FT. - IN.) | Design Press. (PSIG) | Design Temp (F) | Shell Material | No. | Type | Spacing | Material | Weight (LBS) |
| 7-C-1 | Vacuum Tower | 252 | 52 | 25 | 800 | A285C | 52 | Packed | 410SS | 215,000 | ||
| PUMPS | ||||||||||||
| PICS | Item | Description | Flow (gpm) | Head (ft) | Orientation | Manufacturer | Material | Size | Speed (rpm) | HP | Driver | |
| 7-G-1A | Vacuum Resid | 410 | 226 | H | Byron Jackson | CS | 4 X 6 X 8 | 50 | Exp. Proof Motor | |||
| 7-G-1B | Vacuum Resid | 410 | 226 | H | Byron Jackson | CS | 4 X 6 X 8 | 35 | Steam Turbine | |||
| 7-G-2A | Hvy Vacuum Gas Oil | 250 | 4110 | H | Byron Jackson | CS | 10 X 12 X 18 | 250 | Dripproof Motor | |||
| 7-G-2B | Hvy Vacuum Gas Oil | 205 | 4110 | H | Byron Jackson | CS | 10 X 12 X 18 | 205 | Steam Turbine | |||
| 7-G-3A | Light Vacuum Gas Oil | 600 | 0 | H | Byron Jackson | CI | 4 X 6 X 8 | |||||
| 7-G-5A | Sour Water | 48 | 94 | H | Byron Jackson | Alloy 20 | 1 X 1 1/2 X 6 3/4 | 3 | Exp. Proof Motor | |||
| 7-G-5B | Sour Water | 48 | 94 | H | Byron Jackson | Alloy 20 | 1 X 1 1/2 X 6 3/4 | 3 | Exp. Proof Motor | |||
| 7-G-6 | Overflash Resid | 50 | 645 | H | Byron Jackson | CS | 1 1/2 X 2 1/2 X 10 | 30 | Exp. Proof Motor | |||
| 7-G-7A | Tempered Water | 2,500 | 137 | H | Byron Jackson | CS | 8 X 10 X 16 | 125 | Exp. Proof Motor | |||
| 7-G-7B | Tempered Water | 2,500 | 137 | H | Byron Jackson | CS | 8 X 10 X 16 | 125 | Steam Turbine | |||
| 7-G-10 | Hot Well Pumpout | 10 | 250 | H | Viking Roto King | CS | 0 | 2 | TEFC Motor | |||
| VESSELS | ||||||||||||
| PICS | Item | Description | Capacity (gallons) | Diameter (inches) | Length (FT-IN) | Pressure (PSIG) | Temperature (Fahrenheit) | V/H | Material | Weight (lbs) | ||
| 7-C-2 | Hot Well | 2,100 | 54 | 16 | - | 0 | 25 | 650 | H | A-285C | 6,000 | |
| 7-C-3 | Blow Down Drum | 250 | 30 | 6 | - | 0 | 75 | 650 | V | A-285C | 2,000 | |
| 7-C-4 | Fuel Gas | 450 | 36 | 7 | - | 6 | 100 | 650 | V | A-285C | 2,000 | |
| MISCELLANEOUS | ||||||||||||
| PICS | Item | Description | ||||||||||
| 7-D-1 | Tempered Water Tank | |||||||||||
| 7-D-2 | Vacuum Unit Water Sump | |||||||||||
| 7-D-3 | Tempered Water (DM) Tank | |||||||||||
| 7-E-3A | Light Vacuum Pumparound Steam Generator | |||||||||||
| 7-E-3B | Light Vacuum Pumparound Steam Generator | |||||||||||
| 7-E-5A | Tempered Water Air Cooler | |||||||||||
| 7-E-5B | Tempered Water Air Cooler | |||||||||||
| 7-E-5C | Tempered Water Air Cooler | |||||||||||
| 7-E-5D | Tempered Water Air Cooler | |||||||||||
| 7-E-5E | Tempered Water Air Cooler | |||||||||||
| 7-E-5F | Tempered Water Air Cooler | |||||||||||
| 7-E-5G | Tempered Water Air Cooler | |||||||||||
| 7-E-5H | Tempered Water Air Cooler | |||||||||||
| 7-E-6 | 1ST Stage Ejector Condenser | |||||||||||
| 7-E-7 | 2ND Stage Ejector Condenser | |||||||||||
| 7-E-8 | 3RD Stage Ejector Condenser | |||||||||||
| 7-E-10 | Tank Heater for Tempered Water | |||||||||||
| 7-E-12A | Slop Cooler | |||||||||||
| 7-E-12B | Slop Cooler | |||||||||||
| 7-E-13 | Vacuum Tower Recycle Exchanger | |||||||||||
| 7-E-14A | Fallon System Air Preheat Coil | |||||||||||
| 7-E-14B | Fallon System Air Preheat Coil | |||||||||||
| 7-E-15 | Fallon System Air Preheat Coil | |||||||||||
| 7-FC-10 | Heavy Vacuum Gas Oil to Bottom Grid | |||||||||||
| 7-FC-11 | Light Vacuum Gas Oil Lower Reflux | |||||||||||
| 7-FC-15 | Heavy Vacuum Gas Oil Reflux | |||||||||||
| 7-FC-17 | Gas Oil to Hydrotreater Unit/Storage | |||||||||||
| 7-FC-18 | Vacuum Heater Feed-Pass 3 & 4 | |||||||||||
| 7-FC-20 | Vacuum Heater Feed-Pass 1 & 2 | |||||||||||
| 7-FC-21 | Emergency HVGO Circulation to 7-F-1 | |||||||||||
| 7-FC-34 | Coker Feed to Vacuum Heater | |||||||||||
| 7-FC-40 | 7F-1 West Combustion Air | |||||||||||
| 7-FCV-40 | 7F-1 West Combustion Air | |||||||||||
| 7-FC-41 | 7F-1 East Combustion Air | |||||||||||
| 7-FCV-41 | 7F-1 East Combustion Air | |||||||||||
| 7-FC-42 | 7F-1 West Fuel Gas | |||||||||||
| 7-FC-43 | 7F-1 East Fuel Gas | |||||||||||
| 7-FV-9 | Vacuum Column Btms | |||||||||||
| 7-FV-10 | Heavy Vacuum Gas Oil to Bottom Grid | |||||||||||
| 7-FV-11 | Light Vacuum Gas Oil Lower Reflux | |||||||||||
| 7-FV-12 | Light Vacuum Gas Oil Upper Reflux | |||||||||||
| 7-FV-15 | Heavy Vacuum Gas Oil Reflux | |||||||||||
| 7-FV-17 | Gas Oil to hydrotreater unit/storage | |||||||||||
| 7-FV-18 | Vacuum Heater Feed-Pass 3&4 | |||||||||||
| 7-FV-20 | Vacuum Heater Feed-Pass 1&2 | |||||||||||
| 7-FV-21 | Emergency HVGO Circulation to 7F-1 | |||||||||||
| 7-FV-28 | Cold Vacuum Bottoms BTMS to Storage | |||||||||||
| 7-FV-34 | Coker Feed to Vacuum Heater | |||||||||||
| 7-FC-40 | 7F-1 West Combustion Air | |||||||||||
| 7-FV-40 | 7F-1 West Combustion Air | |||||||||||
| 7-FV-41 | 7F-1 East Combustion Air | |||||||||||
| 7-FV-42 | 7F-1 West Fuel Gas | |||||||||||
| 7-FV-43 | 7F-1 East Fuel Gas | |||||||||||
| 7-K-1 | Forced Draft Fan (East) | |||||||||||
| 7-K-2 | Forced Draft Fan(West) | |||||||||||
| 7-K-3 | Induced Draft Fan | |||||||||||
| 7-LC-1 | Vacuum Tower Light Vacuum Gas Oil Pan | |||||||||||
| 7-LC-2A | Vacuum Column Btms | |||||||||||
| 7-LC-2B | Vacuum Column Btms | |||||||||||
| 7-LC-3 | Heavy Vacuum Gas Oil Draw Pan | |||||||||||
| 7-LC-3A | Heavy Vacuum Gas Oil Draw Pan | |||||||||||
| 7-LC-4 | Vacuum Column Overflash | |||||||||||
| 7-LC-5 | BFW to East HVGO Steam Generator | |||||||||||
| 7-LC-6 | BFW to west HVGO Steam Generator | |||||||||||
| 7-C-7 | Hot Well Water Side | |||||||||||
| 7-LC-9 | Cont Blowdown Drum 7C-3 | |||||||||||
| 7-LC-10 | Slop Oil Pump 7G-8 | |||||||||||
| 7-LC-11 | Condensate Flash Drum 7C-5 | |||||||||||
| 7-LV-1 | Vacuum Tower Light Vacuum Gas Oil Pan | |||||||||||
| 7-LV-3 | Heavy Vacuum Gas Oil Draw Pan | |||||||||||
| 7-LV-4 | Vacuum Column Overflash | |||||||||||
| 7-LV-5 | BFW to East HVGO Steam Generator | |||||||||||
| 7-LV-6 | BFW to West HVGO Steam Generator | |||||||||||
| 7-LV-7 | Hot Well Water Side | |||||||||||
| 7-LV-9 | Cont Blowdown Drum 7C-3 | |||||||||||
| 7-LV-10 | Slop Oil Pump 7G-8 | |||||||||||
| 7-LV-11 | Condensate Flash Drum 7C-5 | |||||||||||
| 7-LV-18 | Vacuum Column HVGO Level | |||||||||||
| 7-MO-V1 | 7G-1A Vacuum Resid Suction | |||||||||||
| 7-MO-V2 | 7G-1B Vacuum Resid Suction | |||||||||||
| 7-MO-V3 | 7G-2A Heavy Vacuum Gas Oil Suction | |||||||||||
| 7-MO-V4 | 7G-2B Heavy Vacuum Gas Oil Suction | |||||||||||
| 7-MO-V5 | Vacuum Bottoms Pump 7G-17C Suction Block | |||||||||||
| 7-MO-V6 | Vacuum Bottoms Pump 7G-17A Suction Block | |||||||||||
| 7-MO-V7 | Vacuum Bottoms Pump 7G-17B Suction Block | |||||||||||
| 7-PC-20 | 7F-1 Heater ARCH-ID FAN | |||||||||||
| 7-PC-22 | 7F-1 Stack Damper (ARCH) | |||||||||||
| 7-TC-1 | Vacuum Heater Combined Pump | |||||||||||
| 7-TC-2 | Vacuum Tower Btms 7C-1 | |||||||||||
| 7-TC-20 | ATM/VAC Resid Storage | |||||||||||
| 7-G-11A | Fallon Oil Circulation (West) Pump | |||||||||||